Safety Distance Optimization for Collaborative Robot Systems through PFL Analysis

Learn how to achieve safety and productivity at the same time with SafetyDesigner, the safety analysis software from Safetics.

Reference standards: ISO 10218-1/2, ISO 13855, ISO 13857, ISO/TS 15066, KOROS 1162-1

1. Common Problems and Solutions

A collaborative robot is an 'industrial robot', so the protective measures required by the standards must be put in place just as for any other industrial robot. Typically, the robot is operated in either Speed and Separation Monitoring (SSM) mode, which slows down and stops the robot when an operator approaches, or Power and Force Limiting (PFL) mode, which limits collision force/pressure without fences/sensors.

Problems

  • Space inefficiency: Depending on the robot's operating speed or required stopping time, a large safety distance of about 1.5m to 3m is needed, which greatly reduces space efficiency.
  • Reduced productivity: Because the safety of the reduced speed in SSM mode cannot be proven, either a conservatively low speed is set, or only the final stop zone is used and the system comes to a complete stop every time an operator is detected.
  • Uncertain settings: The speed and distance of the deceleration zone are set based on experience, which makes it difficult to ensure both safety and efficiency.

Solution

  • The safety analysis software SafetyDesigner is used to objectively prove that the robot's operating speed in PFL mode is within the force/pressure limits of ISO/TS 15066.
  • This provides a solution that dramatically shortens the safety distance required by ISO 13855 while maximizing the safe PFL speed.

※ (Note) Requirements of the European Market

In the European market, Stop Time Measurement (STM) is regarded as the state of the art. The stopping/response times provided by the manufacturer can differ from actual site conditions, so if the safety distance is calculated from manufacturer data alone without measured values, safety may not be sufficiently proven in the event of an accident.

2. Example of a Safety Distance Optimization Process Using SafetyDesigner

Collision safety analysis (PFL) and safety sensors (SSM) are combined to verify the safety of the protective measures as follows.

Zone Name Operator Status Robot Motion Applied Protective Measures and Safety Verification Method
Normal operation zone Not detected Maximum speed -
Reduced-speed operation zone
(Warning Zone)
Enters warning zone Reduced-speed operation SafetyDesigner is used to analyze the force/pressure in a collision and derive a robot speed optimized for safety and productivity, and the robot operates at that speed.
Stop zone
(Protective Zone)
Enters stop zone Protective stop When the operator enters a zone where body parts for which dynamic collision is not permitted (head, neck) could be struck, the sensor detects this and stops the robot.

2.1. Step 1: PFL Analysis (SafetyDesigner)

  • Goal: Derive the maximum PFL operating speed to apply in the reduced-speed operation zone.
  • Method: Robot motion data and 3D CAD models (end-effector, work object) are entered into SafetyDesigner to run a collision simulation. The collision expected body parts are set to those the operator can contact in the reduced-speed zone (arm, hand, etc.).
  • Result: The optimal speed that complies with the ISO/TS 15066 force/pressure limits is calculated, and an analysis report proving safety is issued.
    (In this example: normal operation 2,000mm/s → reduced-speed operation 1,300mm/s)
PFL analysis example
PFL analysis result

Drag the slider left and right to compare the SafetyDesigner 3D screen with the analysis result image

2.2. Step 2: Calculating the Deceleration and Stopping Distances

Applying the ISO 13855 Safety Distance Formula
Based on the PFL analysis results from Step 1, the ISO 13855 safety distance formula for horizontal detection is applied to fit the two zones.

Basic formula: S = (K × T) + C
K = hand approach speed (1,600mm/s)
T = total stopping time (sensor response + robot stop)
C = intrusion distance = 1,200 - (0.4 × H)
H = sensor installation height (in this example: 300mm)

Scenario 2-1: (Recommended) Stop Time Measurement Method (STM)

This method uses measuring equipment to measure the actual stopping time and distance and applies those values. From a legal standpoint, it is the most reliable way to ensure safety.

A. Reduced-speed operation zone distance (Sw):
Measuring equipment is used to measure the actual distance the robot travels to decelerate from the maximum speed (2,000mm/s) to the PFL operating speed (1,300mm/s).
(Example measured value: Sw = 289mm)

B. Stop zone distance (Sp):

① Basic safety distance calculation: Apply the measured total stopping time (Tmeasured = 0.4s) to the ISO 13855 formula.
S_p = (1,600 × 0.4) + (1,200 - (0.4 × 300))
= 640 + 1,080 = 1,720mm


② Applying PFL optimization: Because Step 1 proved the safety of an 'arm' collision, the 850mm arm reach distance from ISO 13857 can be subtracted.
S_p = 1,720 - 850 = 870mm

Scenario 2-2: (Alternative) Using the Manufacturer's Stopping Time

This method uses the manufacturer's specifications when no measuring equipment is available, but because of site variables (temperature, load, etc.), it may be difficult to use as a legal basis in some markets such as Europe.

A. Reduced-speed operation zone distance (Sw):
Back-calculate the maximum deceleration (amax = -4,000mm/s²) from the manufacturer's stopping time (e.g., 0.5s) and use it to calculate the deceleration distance.
S_w ≈ 289mm

B. Stop zone distance (Sp):

① Basic safety distance calculation: Add the robot deceleration time (0.325s) and the sensor/PLC response time (0.075s), and assume a total stopping time of Tspec = 0.4s.
S_p = (1,600 × 0.4) + 1,080
= 1,720mm


② Applying PFL optimization: As in Scenario 2-1, subtract the 850mm arm reach distance.
S_p = 1,720 - 850 = 870mm

※ Important: Recommended Minimum Protective Distance

If the final calculated Sp value is less than 850mm, then, in view of the operator's unpredictable behavior (e.g., stepping up beyond the detection zone), setting the minimum protective distance to 850mm or more is recommended.

3. Final Results and Expected Benefits

3.1. Comparative Analysis of Safety Distances

Item Conventional Method
(single protective zone)
Optimized Method
(SSM + PFL)
Reduced-speed operation zone Unknown 289mm
Stop zone 1,720mm 870mm

Move the mouse over the image to compare before and after

Conventional method
Conventional method
1,720mm
Optimized method
Optimized method
1,159mm (-33%)

Benefit 1. Shorter Safety Distance

Shortening the safety distance by about 33% increases workspace efficiency and gives flexibility in equipment layout.

Benefit 2. Maximized Productivity

Instead of stopping immediately when an operator is detected, or slowing to an arbitrary speed whose safety has not been verified, the system keeps operating as long as possible at a PFL speed with verified collision safety, which minimizes downtime.

4. Key Technical Q&A

Q1: Can the robot work at 'head height'?

A: Yes, it can. The purpose of the robot system example above is to use a laser scanner to fundamentally eliminate the risk of a dynamic collision with the operator's head/neck occurring before the robot stops. Likewise, if the robot can be stopped safely before the operator's head reaches it, work at head height is also permitted.

Q2: Doesn't 'face 65N' in ISO/TS 15066 mean that head collisions are permitted?

A: No. 'Quasi-static contact (clamping)' and 'dynamic collision (free collision)' must be clearly distinguished. The 65N specified in the standard is the permissible force when the body is clamped (quasi-static), and the permissible limit for dynamic collision of the head/neck is specified as 'N/A' (not permitted).

Q3: Must the sensor signal that triggers 'reduced-speed operation' be configured as fail-safe (OSSD)?

A: No. The standard requires the 'protective stop' function for operator protection to be implemented as fail-safe. The 'speed reduction' function is a supplementary function for safety, so it can be configured with a normal control signal.

Q4: When subtracting from the safety distance, why is 850mm (arm) applied instead of 1,200mm (upper body)?

A: This is because the body part whose safety was proven by the PFL analysis is the 'arm'. The 1,200mm in ISO 13857 is the maximum reach with the upper body bent forward, and it can include the head/neck. Because SafetyDesigner proved the safety of an 'arm' collision, the 'arm reach distance of 850mm' can be subtracted. Subtracting 1,200mm would require proving head collision safety as well, which, as explained in Q2, is not possible under the standard.